Generators ~ water cooled, sound proofed

Electricity / Power Generators ~ Diesel or LPG

Generators can be either diesel or LPG driven. Genkit's generators can be installed as stand-alone backup units that manually or auto-start when required, eg. when normal grid power is lost. Or the generator may be part of a stand alone system, where it auto-starts to charge a battery bank, or supplement power if solar or wind energy is lost.

For Generating Emergency, or Back-up Power

When it comes to emergency power, generators can play a pivotal role as a back-up system when the electricity fails

Genkit Nelson has built a solid reputation for clean, reliable, long-lasting engines, and generating sets.


Generator Specifications ~ New Zealand

Prime Power Range: 5.5-37 KVA ~ 5.5-29.6 kW
Standby Power Range: 6.4-40.0 KVA ~ 6.4-32.0 kW

genset-data-sheet.jpg: Lister Petter Generators

Genset
Lister Petter
  • two, three, and four cylinder, direct injection, naturally aspirated and four cylinder turbocharged water cooled diesel fuelled engines.

  • Tropical radiator with a pusher fan and full guarding.

  • Standard oil and fuel filters.

  • Heavy duty air cleaner.

  • 12 volt electric starting.

  • Energised to run fuel solenoid.

  • Battery charging alternator.

  • Industrial type exhaust silencer.

L95 or L95/S
LPW2
L135 or L135/S
LPW2
L140 or L140/S
LPW3
L200 or L200/S
LPW3
L190 or L190/S
LPW4
L250 or L250/S
LPWT4
L275 or L275/S
LPW4
L400 or L400/S
LPWT4
L410 or L410/S
DWS4

Mode Of Operation Specifications

Keystart Specification
For local on plant control. Standard features as detailed above with the control system mounted in a panel on a vibration isolated support and including:

  • Module incorporating voltmeter, ammeter, frequency meter and hours run counter.
  • Meter selector switch for single phase 3 wire outputs and 3 phase outputs.
  • Module incorporating oil pressure, coolant temperature and battery condition indicators.
  • Control module for key start operation.
  • Shutdown for low oil pressure and high coolant temperature with separate LED indicators.
  • Battery charge failure LED indication.
  • DC control circuit protection.
  • Plant output ciruit breaker.

Automatic Electric Start
For remote operation with local control selection and on plant operation. All features detailed for the KEY START Specification but with an enhanced AUTO START Control Module for remote operation over a 2 wire circuit, incorporating:

  • Control mode selector switch.
  • Overspeed shutdown.
  • Timer circuits ~ factory preset for specific applications.
  • Protection override timer circuits for the starting period.
  • 3 attempt starter motor cranking timer circuit.

Automatic Mains Failure
Fully automatic operation to supply the load in the event of a failure of the mains supply. All features detailed for the KEY START Specification but with an enhanced AUTO START Control Module for remote operation incorporating:

  • Control mode selector switch.
  • Overspeed shutdown with LED indication.
  • Timer circuits ~ factory preset for delay.
  • Protection override timer circuits for the starting period.
  • Mains powered automatic battery charger.
Separate wall mounting cubicle with the following:
  • Mains supply monitor to control the set operation.
  • Mechanically and electrically interlocked transfer contactors rated for the set output.
  • Mains on load/plant on load indications.
  • Plant contactor emergency operation selector switch.

Standard Features & Options

Standard Features:

  • Engine and alternator close coupled.
  • Fabricated steel skid base.
  • Integral fuel tank with contents gauge.
  • Anti-vibration mounts.
  • 12 volt lead acid starting battery.
  • Battery mounting frame.
  • Battery leads.
  • Operator Handbook.
  • Electrical diagrams as applicable.

Optional Items:

  • Basic tool kit.
  • Road towing trailer.
  • Manual changeover switches.
  • By-pass isolator switches.

Prime & Standby Power Output

Model
r/min
Power
220-230-240
380-220 400/230-415/240
  r/min
220/110 230/115-240/120
220/127 230/133
KVA
kW
KVA
kW
KVA
kW
KVA
kW
L95, L95/S
1500
Prime
5.5
5.5
7.6
6.1
1800
6.6
6.6
9.6
7.7
Standby
6.4
6.4
8.4
6.7
8.1
8.1
10.5
8.4
L135, L135/S
3000
Prime
10.0
10.0
13.6
10.9
Not available
Standby
11.0
11.0
15.0
12.0
L140, L140/S
1500
Prime
8.8
8.8
11.9
9.5
1800
10.8
10.8
14.6
11.7
Standby
9.7
9.7
13.0
10.4
11.9
11.9
16.1
12.8
L190, L190/S
1500
Prime
12.0
12.0
16.0
12.8
1800
15.1
15.1
17.5
14.0
Standby
13.2
13.2
17.6
14.1
16.6
16.6
19.3
15.4
L200, L200/S
3000
Prime
15.4
15.4
20.3
16.3
  
Not available
Standby
16.9
16.9
22.4
17.9
L250, L250/S
1500
Prime
15.4
15.4
20.0
16.0
1800
19.5
19.5
23.0
18.4
Standby
17.0
17.0
22.0
17.6
21.4
21.4
25.3
20.2
L275, L275/S
3000
Prime
20.9
20.9
28.1
22.5
  
Not available
Standby
23.0
23.0
30.9
24.8
L400, L400/S
3000
Prime
Not available
39.5
31.6
  
Not available
Standby
43.5
34.8
L410, 410/S
1500
Prime
Not available
30.0
24.0
1800
Not available
37.0
29.6
Standby
33.0
26.4
40.0
32.0

Approximate Fuel Consumption

 
litres/hour
Model
r/min
100% Load
75% Load
L95/S
1500
1.9
1.8
1800
2.3
2.2
L135/S
3000
3.9
3.1
L140/S
1500
2.8
2.2
1800
3.4
2.7
L190/S
1500
3.8
2.9
1800
4.6
3.6
L200/S
3000
5.9
4.6
L250/S
1500
4.9
3.7
1800
6.9
4.6
L275/S
3000
7.8
6.1
L400/S
3000
10.6
8.3
L410/S
1500
8.6
6.3
1800
10.3
7.4

Rating Definitions to ISO 8528-1

Rating Conditions
A standard generating set is designed to operate in environmental conditions not exceeding an air inlet temperature of 25 C (77 F), altitude (above sea level) 152.4 metres (500 feet) and a relative humidity of 60%.

Prime Power
This rating is for the supply of continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation on the annual hours of operation and 10% overload power can be supplied for 1 hour in 12 hours.

Standby Power
This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted.